Pay in installments of $124.78 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Aug 10 - Aug 15
For Your Every Summer RSVP, with Code: SUMMER15
Description
Dopant - PositiveProduct Overview This positive dopant tube is stored inside the instruments dopant chamber located on the rear of the instrument (identified with a '+'). The dopant is an integral part of the instrument and is required for correct instrument operation. This item should be checked replaced by appropriately trained personnel in accordance with the instructions provided in the instrument's user guide. Rapiscan Systems recommends that you always maintain
Product Overview
This positive dopant tube is stored inside the instruments dopant chamber located on the rear of the instrument (identified with a '+'). The dopant is an integral part of the instrument and is required for correct instrument operation.
This item should be checked/replaced by appropriately trained personnel in accordance with the instructions provided in the instrument's user guide.
Rapiscan Systems recommends that you always maintain an adequate supply of consumables and routine/as-needed maintenance parts in order to ensure uninterrupted operation of your instrument.
Product Information
- Contains Ammonium Carbamate in white powder form
- Dimensions - 144.5 mm x 25.4 mm (L x Dia)
- Spare dopants can be stored in the freezer
- Product life - approximately 2 years in the instrument chamber
- Assumes instrument location is room temperature (20-26oC)
- Assumes operating storage temp of ~45oC
- Shelf Life (approximate)
- In a freezer at 0oC - 3 years
- At room temperature (20-26oC) - 2¼ years
- Assumes plugs or tapes have not been removed
Rapiscan Systems recommends that the positive dopant not be stored in the freezer for longer than 12 months to ensure greater usable life
- Dopant is wrapped in aluminium foil
- Ships in a sealed container (L 158 mm x Dia 44.5 mm) which also contains
- 2 packets of Silica Gel (moisture absorbtion)
- 1 packet of Activated Carbon (odor control)
If you are removing replacement dopants from a freezer, allow 30 minutes for them to reach room temperature before installing them. After installing new dopants, allow 2 hours for the substance to permeate the instrument before resuming operations.
Applicable Product Range
Itemiser 4DX, Itemiser 4DN
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy