SKU: 39663176308

APC NetShelter Metered Rack PDU, 2G, 0U, 15A, 100-120V, 10 NEMA 5-15R outlets

Sale price$415.67 Regular price$461.86
Save 10%

Pay in installments of $115.47 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 14 - Aug 19

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

APC NetShelter Metered Rack PDU, 2G, 0U, 15A, 100-120V, 10 NEMA 5-15R outletsDesigned for high density data centers and server rooms, the APC NetShelter Metered Rack PDU delivers precise energy measurement, proactive protection, and scalable power distribution for critical IT equipment. This metered PDU (2G, 0U) fits standard 19 inch racks and provides reliable, granular visibility into how your devices draw power, helping you optimize energy use, manage costs, and protect circuits from overloads. With 10 NEMA 5 15R outlets, a

Designed for high-density data centers and server rooms, the APC NetShelter Metered Rack PDU delivers precise energy measurement, proactive protection, and scalable power distribution for critical IT equipment. This metered PDU (2G, 0U) fits standard 19-inch racks and provides reliable, granular visibility into how your devices draw power, helping you optimize energy use, manage costs, and protect circuits from overloads. With 10 NEMA 5-15R outlets, a compact 0U footprint, and a 15A, 100-120V power rating, it’s a compact, powerful solution for modern data center environments that demand efficiency without sacrificing reliability.

  • Active metering and energy optimization: The NetShelter Metered Rack PDU continuously measures power usage at the outlet and total levels. Real-time energy data helps IT teams identify under- or over-utilized circuits, optimize workload placement, and drive cost savings. With per-outlet and total power metrics, you can pinpoint which devices drive consumption and implement targeted efficiency initiatives, ultimately improving data center ROI.
  • User-defined alarm thresholds and real-time alerts: Stay ahead of potential issues with customizable alarm thresholds. The PDU raises local alarms and supports remote alerts to warning systems, letting facilities and IT staff respond quickly to nearing circuit overloads. This proactive approach reduces downtime risk and protects sensitive equipment from power-related problems, enhancing overall data-center reliability.
  • Compact 0U, rack-mount form factor: Engineered for space-constrained environments, the 0U footprint fits seamlessly in 19-inch racks without consuming valuable rack space. The slim profile keeps power distribution close to the equipment it serves, delivering clean cable management and easy access to outlets while maintaining ample clearance for airflow and maintenance.
  • Durable, mission-critical design for APC NetShelter deployments: Built to endure the rigors of data center operation, this PDU complements APC NetShelter enclosures and other traditional 19-inch racks. The rugged construction supports continuous operation under demanding load conditions, and the simple mounting hardware makes installation straightforward for data-center technicians and facilities teams alike.
  • Comprehensive power utilization data for smarter decisions: Beyond simply delivering outlets, the Metered Rack PDU captures and reports power usage trends, aiding capacity planning and energy reporting. IT managers can leverage this data for audits, sustainability reporting, and ongoing optimization of IT infrastructure, aligning power consumption with business growth and IT strategy.

Technical Details of APC NetShelter Metered Rack PDU, 2G, 0U, 15A, 100-120V, 10 NEMA 5-15R outlets

  • Voltage: 100–120V
  • Current rating: 15A
  • Outlets: 10 NEMA 5-15R
  • Mounting: 0U, fits standard 19-inch racks
  • Form factor: Metered rack PDU (2G variant)
  • Metering: Active energy measurement with per-outlet and total power data
  • Alerts: User-defined alarm thresholds with local and remote notification
  • Power distribution: Dedicated, organized outlet network for IT equipment
  • Brand: APC by Schneider Electric
  • Typical use: Data centers, server rooms, network closets requiring precise energy management

How to install APC NetShelter Metered Rack PDU

Installing the APC NetShelter Metered Rack PDU is a straightforward process designed for IT staff and facilities professionals. The following steps provide a practical guide to mount, connect, and configure the 0U PDU for optimal power delivery and energy monitoring in a standard 19-inch rack environment.

1) Plan and verify compatibility: Confirm that your rack supports 0U PDUs and that the electrical circuit (100–120V, 15A) aligns with your facility’s power supply. Review your data-center’s power distribution strategy to determine whether this metered PDU should serve your critical servers, storage devices, and network equipment.

2) Prepare the rack and PDU: Inspect the rack, clean the mounting area, and prepare the mounting hardware included with the PDU. Ensure there are clear paths for cable management and adequate airflow around the unit to prevent overheating. The 0U design allows the PDU to be mounted in the rear or along the side of the rack as needed, depending on your cabling layout.

3) Mount the PDU: Align the PDU’s mounting flanges with the rack’s vertical rails and secure it using the provided screws or mounting hardware. The 0U form factor keeps the unit low-profile and unobtrusive, preserving valuable rack space for equipment while maintaining efficient power distribution to connected devices.

4) Connect power and loads: Connect the incoming power cord to a suitable 100–120V, 15A power source. Route the 10 NEMA 5-15R outlets to your IT equipment in an organized manner, using cable management accessories to minimize clutter and maximize airflow. Ensure cords are not kinked or strained and that outlet usage does not exceed the PDU’s rating.

5) Configure metering and alerts: Access the PDU’s local interface (and any remote management solutions your setup uses) to configure alarm thresholds, metering intervals, and alert destinations. Set thresholds based on typical load patterns to receive timely warnings of potential overloads. Review metering data after initial operation to validate that energy usage is being tracked accurately and that reporting aligns with your reporting requirements.

6) Validate functionality and performance: Power on connected equipment and verify that all outlets function correctly. Confirm that metering readings appear in the management interface and that alerts trigger when thresholds are approached or exceeded. Document the installation for future reference and ensure ongoing maintenance aligns with your data-center operating procedures.

Frequently asked questions

  • What is a metered PDU? A metered PDU provides active power metering and energy data for each outlet or group of outlets, enabling you to monitor consumption, optimize energy use, and protect circuits from overloads with real-time information and alarms.
  • What does 0U mean? 0U refers to the PDU’s height in the rack unit measurement. A 0U PDU sits flush with the rack’s rear space, occupying no vertical space and leaving rack units free for other equipment while still delivering power distribution to connected devices.
  • What does 2G indicate in this model? The 2G designation identifies the model variant within APC’s NetShelter Metered PDU family. It distinguishes the unit’s metering configuration and form factor. For precise feature matching, refer to APC product documentation or specifications for the exact model variant you’re using.
  • Is this PDU compatible with non-APC racks? Yes. This 0U, 19-inch rack-compatible PDU is designed to fit standard 19-inch rack cabinets and can be used in non-APC racks as long as there is suitable mounting space and clearance. Always verify mounting hardware compatibility and electrical safety requirements for your facility.
  • Can I monitor this PDU remotely? Yes. The Metered Rack PDU provides energy data and alarm information that can be integrated with remote monitoring solutions. Real-time alerts and utilization data support centralized management, capacity planning, and energy reporting across your data center.
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 39663176308

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.0 ★★★★★
Based on 17 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
M
Verified Purchase
MasterTarl
Lake Worth, US
★★★★★ 4
Works with effort
Size: 1-Gallon (128 oz)
I was skeptical about buying this. However, after installing the recommended ozs per tire, it seems to have fixed the two flats on my zero-turn lawnmower. I will continue to monitor the pressure, but it's held for four days at the time of this review. Caution. Even with a flat tire and no air, pumping the product into the tire builds backpressure, and the internal two-piece pump shaft blew apart on me; afterward, the hose connecting to the value stem blew off. In short, a lot of fluid was lost. Finally, the bottleneck of the pump collapsed when the bottle was only half empty. It's not as smooth an install as you are led to believe. It is a good concept, but the pump bottle is cheaply made and does not hold up well to deliver all the product to the tires. It fatigues after around 50 - 60 pumps, and you wind up struggling to get the job done.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 31, 2023
F
Verified Purchase
Frances
Charlottesville, US
★★★★★ 5
It did work
Size: 1-Pack (32 oz)
Sealed a small nail hole in a front tractor tire. Better than taking to shop for inside patch or making the 3x bigger for a rope patch.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 6, 2026
J
Verified Purchase
Jim
Whiting, US
★★★★★ 5
Fixed a Bead Sealing Issue
Size: 1-Gallon (128 oz)
For traction in snow, I recently installed new "agricultural" style lugged front tires on a Simplicity garden tractor from around 1980. The tractor looks like it's survived a war, evidently having had a hard life as a workhorse owned by a school district. The front rims are rusty, and I naively thought the beads of these thick tires would seal properly anyway. They didn't. The jug of sealant ships with a valve core removal tool. Removing and reinstalling the cores is a piece of cake if you've never done it. I pumped a generous amount of the product into each tire and then did a few fast laps in a grassy paddock. It's a Kohler 19HP twin and it's a bit of a rocket. 😎 One tire sealed, the other didn't, and there was still a faint hiss. I added more product to that side and repeated the process. It seemed to hold. The next day that side was flat again, so I added more sealant and this time it held. Based on this experience, I'd say that instead of strictly following what the instructions recommended as an amount per tire, keep adding product in increments until the tire holds air. It's good stuff and it works. Will the tire self-heal if I puncture it? I don't know yet. It saved me the headache of having to remount these small tires or install tubes.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 24, 2026
S
Verified Purchase
shimshong
Lake Worth, US
★★★★★ 5
Stop wasting your money on green slime or Fix-A-Flat or any of the other tire sealant
Size: 1-Gallon (128 oz)
Flat out is by far the best product on the market to fix flat tires and prevent flat tires. This will be the second gallon jug that I purchased that stuff on everything. all of my landscape equipment has it in every tire. And to paint and even better picture for you I have a scag mower that is 20 years old The tires are probably 18 years old ugly as could be and would not hold air until I put the flat out in it it has been sitting now for over a year and every tire still has air That's how good the stuff is. Don't just buy one gallon by two cuz it will get used
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 11, 2025
A
Verified Purchase
Amazon Customer
Port Orchard, US
★★★★★ 5
John Deere 5x4 (gator)
Size: 4-Pack (128 oz), Size: 4-Pack (128 oz)
Excellent product. The John Deere 5x4 (Gator) in picture sat for ten years, the tires were flat, the front tire was the worse. To move this Gator from my neighbors place he had to load it on a trailer, he aired up the rear 4 tires but the front would air up and leak before he could move it. He put a make do wheel to get it moved to my place. shortly after unloading the rear 4 tires went flat. All were badly weathered. I read about a stop leak "FLATOUT" I ordered one bottle and put it in the front wheel and I aired it up, it held air for several hours. I called FLATOUT Support and told them I put 1/2 bottle in front tire and how it helped, He said it calls for a full bottle per tire so I added the rest of the FLATOUT. I bought four more bottles of FLATOUT and put those in all 4 tires, put air in and drove the unit a block. next day two tires were low so I finished putting FLATOUT in and aired the tires and drove two to three blocks. the weather snowed so I parked the Gator for two weeks, the tires never went flat. I checked the air pressure and had lost about 2-3 pounds, refilled with air and on a warm day drove the Gator about 2 miles. No flat tires. Note the front tire had a weathered crack 4 inches long where it sat folded for so many years and I saw where this product had sealed this leak and no air loss after two weeks of sitting.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 7, 2021

recommand products