H150-2100-LT Water ChillerOverview The LabTechs state of the art water chillers ensure accurate and constant cooling conditions of instruments even in the harsh laboratory conditions. Temp. Range 2035 Temp. Stability 0. 1 Temp. Control Mode PID Cooling Capacity 2100W@25 200W@ 15 Pump Flow 12. 1L min LWH 291826 inches Weight 203 lbs Power Supply 230V,50 60Hz Warranty 12 Months FAQ What are the size of the inlet outlet ports on the H Series chillers? They are pipe thread size (.
Overview
The LabTech’s state-of-the-art water chillers ensure accurate and constant cooling conditions of instruments even in the harsh laboratory conditions.
Temp. Range -20℃~35℃
Temp. Stability ±0.1℃
Temp. Control Mode PID
Cooling Capacity 2100W@25℃
200W@-15℃
Pump Flow 12.1L/min
L×W×H 29×18×26 inches
Weight 203 lbs
Power Supply 230V,50/60Hz
Warranty 12 Months
FAQ
What are the size of the inlet / outlet ports on the H Series chillers?
They are ½ pipe thread size (.84”O.D.) ports.
The H Series chillers list a maximum pump flow; is the pump flow adjustable?
All H Series Recirculating Chillers have a relief valve that can be used to adjust the unit’s operating pressure and flow rate. There is a pressure gauge built into the front of the instrument to read the relief valve setting. By releasing pressure through the relief valve, a lower flow rate can be achieved.
Is it okay to run an H Series chiller at maximum load and under continuous operation?
The H Series chillers are designed for continuous operation, but it is not recommended that you do so under maximum load. Likewise, running at maximum load is acceptable for non-continuous usage. Like any equipment, the more stress the unit experiences the shorter the lifespan will be, however running an H Series chiller continuously at max load leads to a high failure rate.
Is the H150-2100-LT Chiller UL listed or CSA certified?
Not currently
Do the H Series Recirculating Chillers have a low-level shutoff?
Yes. If the water level gets too low in the reservoir, they will automatically shut off.
How are the H Series Recirculating Chillers cooled? What is the refrigerant used?
The H Series Chillers are compressor cooled. The H150 series uses R404A refrigerant.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy